Properties | Test Method | Performance |
Continuous operating temperature (℃) | IEC 216 | -55~110 |
Tensile strength (MPa) | ASTM D2671 | ≥14 |
Ultimate elongation (%) | ASTM D2671 | ≥400 |
Heat aging | 150℃, 168h | - |
Tensile strength after aging (MPa) | ASTM D2671 | ≥12 |
Ultimate elongation after aging (%) | ASTM D2671 | ≥300 |
Volume resistivity (Ω·cm) | IEC 93 | ≥1.0*1014 Ω·cm |
Dielectric strength (kV/mm) | IEC 243 | ≥20 |
Longitudinal change (%) | UL224 | 0~10 |
Concentricity (%) | ASTM D2671 | ≥65 |
Cracking resistance | ASTMD1693(50℃) | No cracking |
Water absorption (%) | ISO 62 | 0.2 |